Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Pers Med ; 12(4)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35455769

RESUMO

BACKGROUND: In the multimodal breast-conserving curative therapy of some high-risk breast cancer patients, extended external beam radiotherapy (EBRT) not only to the breast but also to the supraclavicular fossa and the internal mammary chain (parasternal region (PSR)) is indicated. We report a dosimetric study on the EBRT of the breast ("B") and the breast including PSR ("B + PSR"), comparing the supine and the laterally tilted prone patient positions in free breathing. METHODS: The planning CT scans of 20 left- and 20 right-sided patients were analyzed. EBRT plans were calculated with 3D conformal EBRT (3D) and with intensity-modulated EBRT (IMRT) for "B" and "B + PSR" in the prone and supine positions. The mean and threshold doses were computed. The quality of EBRT plans was compared with an overall plan assessment factor (OPAF), comprising three subfactors, homogeneity, conformity, and radiogenic exposure of OAR. RESULTS: In the EBRT of "B", prone positioning significantly reduced the exposure of the OARs "heart" and "ipsilateral lung" and "lymphatic regions". The OPAF was significantly better in the prone position, regardless of the planning technique or the treated breast side. In the EBRT of "B + PSR", supine positioning significantly reduced the OAR "heart" exposure but increased the dose to the OARs "ipsilateral lung" and "lymphatic regions". There were no significant differences for the OPAF, independent of the irradiated breast side. Only the IMRT planning technique increased the chance of a comparatively good EBRT plan. CONCLUSION: Free breathing prone positioning significantly improves plan quality in the EBRT of the breast but not in the EBRT of the breast + PSR.

2.
Nuklearmedizin ; 61(4): 333-338, 2022 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-35388445

RESUMO

OBJECTIVES: In addition to the well-established therapy with iodine-131, treatments with lutetium-177 are increasingly being performed on an inpatient basis in Germany. All of these treatments have be taken into account when assessing the potential internal dose and for incorporation monitoring of personnel. This article describes the experience with and the results of incorporation monitoring of staff of a nuclear medicine ward of a university hospital in Germany. METHODS: Personnel working in a nuclear medicine ward was regularly measured using a whole body counter. In total, 234 measurements were performed over a period of 12 months. Incorporation factors were determined considering activities handled or applied to patients in the respective time period. RESULTS: In approx. 74 % of measurements, no incorporations was found. In the remaining measurements, activity was detected. Assuming incorporation, the maximum effective dose would be less than 0.15 mSv per measurement. The incorporation factors determined in this work were in the order of magnitude of 10-7 for all groups except for personnel performing radiochemical quality control. For this group, only an upper limit of the incorporation factor of 10-5 can be specified. CONCLUSION: The risk of incorporating radiactivity can be considered low for personnel working in a nuclear medicine ward. An incorporation factor of 10-7 is appropriate for medical, nursing, and cleaning staff and personnel performing radiochemical syntheses.


Assuntos
Medicina Nuclear , Exposição Ocupacional , Hospitais , Humanos , Radioisótopos do Iodo/uso terapêutico , Lutécio , Exposição Ocupacional/análise , Radioisótopos , Compostos Radiofarmacêuticos/uso terapêutico
4.
Eur J Nucl Med Mol Imaging ; 49(1): 234-245, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33978829

RESUMO

PURPOSE: Calcineurin inhibitors (CNI) can cause long-term impairment of brain function. Possible pathomechanisms include alterations of the cerebral immune system. This study used positron emission tomography (PET) imaging with the translocator protein (TSPO) ligand 18F-GE-180 to evaluate microglial activation in liver-transplanted patients under different regimens of immunosuppression. METHODS: PET was performed in 22 liver-transplanted patients (3 CNI free, 9 with low-dose CNI, 10 with standard-dose CNI immunosuppression) and 9 healthy controls. The total distribution volume (VT) estimated in 12 volumes-of-interest was analyzed regarding TSPO genotype, CNI therapy, and cognitive performance. RESULTS: In controls, VT was about 80% higher in high affinity binders (n = 5) compared to mixed affinity binders (n = 3). Mean VT corrected for TSPO genotype was significantly lower in patients compared to controls, especially in patients in whom CNI dose had been reduced because of nephrotoxic side effect. CONCLUSION: Our results provide evidence of chronic suppression of microglial activity in liver-transplanted patients under CNI therapy especially in patients with high sensitivity to CNI toxicity.


Assuntos
Transplante de Fígado , Microglia , Encéfalo/metabolismo , Humanos , Terapia de Imunossupressão/efeitos adversos , Microglia/metabolismo , Tomografia por Emissão de Pósitrons , Receptores de GABA/metabolismo
5.
J Nucl Med ; 62(1): 37-42, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32385164

RESUMO

The value of interim 18F-FDG PET/CT (iPET)-guided treatment decisions in patients with diffuse large B-cell lymphoma (DLBCL) has been the subject of much debate. This investigation focuses on a comparison of the Deauville score and the change-in-SUVmax (ΔSUVmax) approach-2 methods to assess early metabolic response to standard chemotherapy in DLBCL. Methods: Of 609 DLBCL patients participating in the PET-Guided Therapy of Aggressive Non-Hodgkin Lymphomas trial, iPET scans of 596 patients originally evaluated using the ΔSUVmax method were available for post hoc assessment of the Deauville score. A commonly used definition of an unfavorable iPET result according to the Deauville score is an uptake greater than that of the liver, whereas an unfavorable iPET scan with regard to the ΔSUVmax approach is characterized as a relative reduction of the SUVmax between baseline and iPET staging of less than or equal to 66%. We investigated the 2 methods' correlation and concordance by Spearman rank correlation coefficient and the agreement in classification, respectively. We further used Kaplan-Meier curves and Cox regression to assess differences in survival between patient subgroups defined by the prespecified cutoffs. Time-dependent receiver-operating-characteristic curve analysis provided information on the methods' respective discrimination performance. Results: Deauville score and ΔSUVmax approach differed in their iPET-based prognosis. The ΔSUVmax approach outperformed the Deauville score in terms of discrimination performance-most likely because of a high number of false-positive decisions by the Deauville score. Cutoff-independent discrimination performance remained low for both methods, but cutoff-related analyses showed promising results. Both favored the ΔSUVmax approach, for example, for the segregation by iPET response, where the event-free survival hazard ratio was 3.14 (95% confidence interval, 2.22-4.46) for ΔSUVmax and 1.70 (95% confidence interval, 1.29-2.24) for the Deauville score. Conclusion: When considering treatment intensification, the currently used Deauville score cutoff of an uptake above that of the liver seems to be inappropriate and associated with potential harm for DLBCL patients. The ΔSUVmax criterion of a relative reduction in SUVmax of less than or equal to 66% should be considered as an alternative.


Assuntos
Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
6.
Rofo ; 193(7): 778-786, 2021 Jul.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-33327031

RESUMO

BACKGROUND: The exposure of a pregnant woman to X-rays is an event that can cause uncertainty for all concerned. This review provides guidance on how to assess such a situation and how to determine the dose to the unborn child. In general, the use of X-rays in pregnant women in radiology should be avoided. If possible, alternatives should be used, or examinations postponed to a time after the pregnancy. This review gives a summary of the procedure for determining the radiation exposure of a pregnant woman. METHOD: Based on the previous report of 2002 and the literature on prenatal radiation exposure published thereafter, the DGMP/DRG report on the procedure for the assessment of prenatal radiation exposure was adapted to the current state of science and technology. RESULTS: Typically, only relatively low radiation exposures of less than 20 mSv occur for the unborn child in X-ray diagnostics in the vast majority of cases. At these dose level the additional risk of damage to the embryo or fetus caused by the radiation is low and therefore only a rough conservative estimate using tabulated values are made. Only in a few types of examination (CT and interventional radiology) higher doses values might occur in the uterus. Instead of dose estimates (step 1 in the two-step model) in these cases the calculation of dose (step 2) are required and further action by the physician may be necessary. CONCLUSIONS: During the assessment, it is useful to initially use simple conservative estimation procedures to quickly determine whether a case falls into this large group less than 20 mSv, where there is a very low risk to the unborn child. If this is the case, the pregnant woman should be informed immediately by the doctor who performed the examination/treatment. This avoids a psychological burden on the patient. The DGMP/DRG report suggests a relatively simple, clearly structured procedure with advantages for all parties involved (physician, medical physics experts, MTRA and patient). KEY POINTS: · The DGMP/DRG report on prenatal radiation exposure describes the procedure for calculating radiation exposures and the associated risks for the unborn child.. · Using the two-step model, only a simple assessment based on the first step is necessary for most prenatal radiation exposures.. · With the given tables it is possible to estimate individual risks for the unborn child taking into account the radiation exposure.. · Only in the rare case that the first estimate results in a uterine dose larger 20 mSv a more accurate calculation is necessary.. CITATION FORMAT: · Fiebich M, Block A, Borowski M et al. Prenatal radiation exposure in diagnostic and interventional radiology. Fortschr Röntgenstr 2021; 193: 778 - 786.


Assuntos
Feto/efeitos da radiação , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiologia Intervencionista , Relação Dose-Resposta à Radiação , Feminino , Humanos , Gravidez , Exposição à Radiação/análise
7.
Z Med Phys ; 31(1): 58-64, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33309149

RESUMO

A multicenter study was conducted to assess the radiation exposure of relatives and caregivers of patients suffering from castration resistant prostate cancer with bone metastases and treated with Ra-223 dichloride in an outpatient setting. As Ra-223 and most of its progeny emit alpha particles, especially the internal exposure of persons in the patient's vicinity had to be evaluated. METHODS: The external radiation was measured in distances of 1 m and 2 m. Wipe-tests were taken in the patients' homes to identify significant contaminations and evaluated by liquid scintillation counting. Samples of saliva and sweat were taken and measured using gamma spectrometry. RESULTS: The external exposure from the patients measured 10-20min post injection (p. i.) was<0.080µSv/h in median in 1 m distance (range: below decision threshold (

Assuntos
Cuidadores , Família , Exposição à Radiação/análise , Rádio (Elemento)/efeitos adversos , Humanos , Exposição à Radiação/efeitos adversos
8.
Front Neurosci ; 14: 787, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32848560

RESUMO

Cochlear implantation constitutes a successful therapy of inner ear deafness, with the majority of patients showing good outcomes. There is, however, still some unexplained variability in outcomes with a number of cochlear-implant (CI) users, showing major limitations in speech comprehension. The current study used a multimodal diagnostic approach combining single-photon emission computed tomography (SPECT) and electroencephalography (EEG) to examine the mechanisms underlying speech processing in postlingually deafened CI users (N = 21). In one session, the participants performed a speech discrimination task, during which a 96-channel EEG was recorded and the perfusions marker 99mTc-HMPAO was injected intravenously. The SPECT scan was acquired 1.5 h after injection to measure the cortical activity during the speech task. The second session included a SPECT scan after injection without stimulation at rest. Analysis of EEG and SPECT data showed N400 and P600 event-related potentials (ERPs) particularly evoked by semantic violations in the sentences, and enhanced perfusion in a temporo-frontal network during task compared to rest, involving the auditory cortex bilaterally and Broca's area. Moreover, higher performance in testing for word recognition and verbal intelligence strongly correlated to the activation in this network during the speech task. However, comparing CI users with lower and higher speech intelligibility [median split with cutoff + 7.6 dB signal-to-noise ratio (SNR) in the Göttinger sentence test] revealed for CI users with higher performance additional activations of parietal and occipital regions and for those with lower performance stronger activation of superior frontal areas. Furthermore, SPECT activity was tightly coupled with EEG and cognitive abilities, as indicated by correlations between (1) cortical activation and the amplitudes in EEG, N400 (temporal and occipital areas)/P600 (parietal and occipital areas) and (2) between cortical activation in left-sided temporal and bilateral occipital/parietal areas and working memory capacity. These results suggest the recruitment of a temporo-frontal network in CI users during speech processing and a close connection between ERP effects and cortical activation in CI users. The observed differences in speech-evoked cortical activation patterns for CI users with higher and lower speech intelligibility suggest distinct processing strategies during speech rehabilitation with CI.

9.
Eur J Nucl Med Mol Imaging ; 47(12): 2887-2900, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32322915

RESUMO

PURPOSE: Tracer kinetic modeling of tissue time activity curves and the individual input function based on arterial blood sampling and metabolite correction is the gold standard for quantitative characterization of microglia activation by PET with the translocator protein (TSPO) ligand 18F-GE-180. This study tested simplified methods for quantification of 18F-GE-180 PET. METHODS: Dynamic 18F-GE-180 PET with arterial blood sampling and metabolite correction was performed in five healthy volunteers and 20 liver-transplanted patients. Population-based input function templates were generated by averaging individual input functions normalized to the total area under the input function using a leave-one-out approach. Individual population-based input functions were obtained by scaling the input function template with the individual parent activity concentration of 18F-GE-180 in arterial plasma in a blood sample drawn at 27.5 min or by the individual administered tracer activity, respectively. The total 18F-GE-180 distribution volume (VT) was estimated in 12 regions-of-interest (ROIs) by the invasive Logan plot using the measured or the population-based input functions. Late ROI-to-whole-blood and ROI-to-cerebellum ratio were also computed. RESULTS: Correlation with the reference VT (with individually measured input function) was very high for VT with the population-based input function scaled with the blood sample and for the ROI-to-whole-blood ratio (Pearson correlation coefficient = 0.989 ± 0.006 and 0.970 ± 0.005). The correlation was only moderate for VT with the population-based input function scaled with tracer activity dose and for the ROI-to-cerebellum ratio (0.653 ± 0.074 and 0.384 ± 0.177). Reference VT, population-based VT with scaling by the blood sample, and ROI-to-whole-blood ratio were sensitive to the TSPO gene polymorphism. Population-based VT with scaling to the administered tracer activity and the ROI-to-cerebellum ratio failed to detect a polymorphism effect. CONCLUSION: These results support the use of a population-based input function scaled with a single blood sample or the ROI-to-whole-blood ratio at a late time point for simplified quantitative analysis of 18F-GE-180 PET.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Carbazóis , Humanos , Receptores de GABA/metabolismo , Reprodutibilidade dos Testes
10.
Appl Radiat Isot ; 151: 310-316, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31279317

RESUMO

The alpha-emitting radionuclide Ra-223 is used in nuclear medicine in form of the commercially available radiopharmaceutical "Xofigo". The direct progeny of Ra-223 is Rn-219, a noble gas with a half-life of approx. four seconds, that might be exhaled by patients treated with Ra-223. For assessing the exhalation of Rn-219, a radon monitor calibrated for this isotope is necessary. This work investigates on the response of the commercially available Alphaguard radon monitor to Rn-219 and proposes for the first time a factor for the calculation of the Rn-219-concentration in the instrument's measurement chamber from the instrument reading suitable for estimating patients exhalations.


Assuntos
Monitoramento de Radiação/instrumentação , Produtos de Decaimento de Radônio/análise , Calibragem , Humanos
11.
PLoS One ; 13(10): e0205044, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30278068

RESUMO

Activation studies with positron emission tomography (PET) in auditory implant users explained some of the mechanisms underlying the variability of achieved speech comprehension. Since future developments of auditory implants will include studies in rodents, we aimed to inversely translate functional PET imaging to rats. In normal hearing rats, activity in auditory and non-auditory regions was studied using 18F-fluorodeoxyglucose (18F-FDG) PET with 3 different acoustic conditions: sound attenuated laboratory background, continuous white noise and rippled noise. Additionally, bilateral cochlea ablated animals were scanned. 3D image data were transferred into a stereotaxic standard space and evaluated using volume of interest (VOI) analyses and statistical parametric mapping (SPM). In normal hearing rats alongside the auditory pathway consistent activations of the nucleus cochlearis (NC), olivary complex (OC) and inferior colliculus (IC) were seen comparing stimuli with background. In this respect, no increased activation could be detected in the auditory cortex (AC), which even showed deactivation with white noise stimulation. Nevertheless, higher activity in the AC in normal hearing rats was observed for all 3 auditory conditions against the cochlea ablated status. Vice versa, in ablated status activity in the olfactory nucleus (ON) was higher compared to all auditory conditions in normal hearing rats. Our results indicate that activations can be demonstrated in normal hearing animals based on 18F-FDG PET in nuclei along the central auditory pathway with different types of noise stimuli. However, in the AC missing activation with respect to the background advises the need for more rigorous background noise attenuation for non-invasive reference conditions. Finally, our data suggest cross-modal activation of the olfactory system following cochlea ablation-underlining, that 18F-FDG PET appears to be well suited to study plasticity in rat models for cochlear implantation.


Assuntos
Técnicas de Ablação , Estimulação Acústica , Vias Auditivas/diagnóstico por imagem , Vias Auditivas/fisiologia , Cóclea/cirurgia , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Animais , Córtex Auditivo/diagnóstico por imagem , Córtex Auditivo/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Feminino , Ratos , Ratos Sprague-Dawley
12.
Eur J Nucl Med Mol Imaging ; 45(11): 1934-1944, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29967943

RESUMO

PURPOSE: The chemokine receptor CXCR4 is a promising target for molecular imaging of CXCR4+ cell types, e.g. inflammatory cells, in cardiovascular diseases. We speculated that a specific CXCR4 ligand, [68Ga]pentixafor, along with novel techniques for motion correction, would facilitate the in vivo characterization of CXCR4 expression in small culprit and nonculprit coronary atherosclerotic lesions after acute myocardial infarction by motion-corrected targeted PET/CT. METHODS: CXCR4 expression was analysed ex vivo in separately obtained arterial wall specimens. [68Ga]Pentixafor PET/CT was performed in 37 patients after stent-based reperfusion for a first acute ST-segment elevation myocardial infarction. List-mode PET data were reconstructed to five different datasets using cardiac and/or respiratory gating. Guided by CT for localization, the PET signals of culprit and various groups of nonculprit coronary lesions were analysed and compared. RESULTS: Ex vivo, CXCR4 was upregulated in atherosclerotic lesions, and mainly colocalized with CD68+ inflammatory cells. In vivo, elevated CXCR4 expression was detected in culprit and nonculprit lesions, and the strongest CXCR4 PET signal (median SUVmax 1.96; interquartile range, IQR, 1.55-2.31) was observed in culprit coronary artery lesions. Stented nonculprit lesions (median SUVmax 1.45, IQR 1.23-1.88; P = 0.048) and hot spots in naive remote coronary segments (median SUVmax 1.34, IQR 1.23-1.74; P = 0.0005) showed significantly lower levels of CXCR4 expression. Dual cardiac/respiratory gating provided the strongest CXCR4 PET signal and the highest lesion detectability. CONCLUSION: We demonstrated the basic feasibility of motion-corrected targeted PET/CT imaging of CXCR4 expression in coronary artery lesions, which was triggered by vessel wall inflammation but also by stent-induced injury. This novel methodology may serve as a platform for future diagnostic and therapeutic clinical studies targeting the biology of coronary atherosclerotic plaque.


Assuntos
Complexos de Coordenação , Regulação Neoplásica da Expressão Gênica , Movimento , Peptídeos Cíclicos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Receptores CXCR4/metabolismo , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Placa Aterosclerótica/complicações , Placa Aterosclerótica/fisiopatologia , Respiração , Estudos Retrospectivos
13.
J Clin Oncol ; 36(20): 2024-2034, 2018 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-29750632

RESUMO

Purpose Interim positron emission tomography (PET) using the tracer, [18F]fluorodeoxyglucose, may predict outcomes in patients with aggressive non-Hodgkin lymphomas. We assessed whether PET can guide therapy in patients who are treated with cyclophosphamide, doxorubicin, vincristine, and prednisone (CHOP). Patients and Methods Newly diagnosed patients received two cycles of CHOP-plus rituximab (R-CHOP) in CD20-positive lymphomas-followed by a PET scan that was evaluated using the ΔSUVmax method. PET-positive patients were randomly assigned to receive six additional cycles of R-CHOP or six blocks of an intensive Burkitt's lymphoma protocol. PET-negative patients with CD20-positive lymphomas were randomly assigned or allocated to receive four additional cycles of R-CHOP or the same treatment with two additional doses rituximab. The primary end point was event-free survival time as assessed by log-rank test. Results Interim PET was positive in 108 (12.5%) and negative in 754 (87.5%) of 862 patients treated, with statistically significant differences in event-free survival and overall survival. Among PET-positive patients, 52 were randomly assigned to R-CHOP and 56 to the Burkitt protocol, with 2-year event-free survival rates of 42.0% (95% CI, 28.2% to 55.2%) and 31.6% (95% CI, 19.3% to 44.6%), respectively (hazard ratio, 1.501 [95% CI, 0.896 to 2.514]; P = .1229). The Burkitt protocol produced significantly more toxicity. Of 754 PET-negative patients, 255 underwent random assignment (129 to R-CHOP and 126 to R-CHOP with additional rituximab). Event-free survival rates were 76.4% (95% CI, 68.0% to 82.8%) and 73.5% (95% CI, 64.8% to 80.4%), respectively (hazard ratio, 1.048 [95% CI, 0.684 to 1.606]; P = .8305). Outcome prediction by PET was independent of the International Prognostic Index. Results in diffuse large B-cell lymphoma were similar to those in the total group. Conclusion Interim PET predicted survival in patients with aggressive lymphomas treated with R-CHOP. PET-based treatment intensification did not improve outcome.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Linfoma não Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Ciclofosfamida/administração & dosagem , Ciclofosfamida/efeitos adversos , Intervalo Livre de Doença , Doxorrubicina/administração & dosagem , Doxorrubicina/efeitos adversos , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Prednisona/administração & dosagem , Prednisona/efeitos adversos , Prognóstico , Rituximab/administração & dosagem , Rituximab/efeitos adversos , Resultado do Tratamento , Vincristina/administração & dosagem , Vincristina/efeitos adversos
14.
EJNMMI Res ; 8(1): 11, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29404708

RESUMO

BACKGROUND: 15O-Water positron emission tomography (PET) enables functional imaging of the auditory system during stimulation via a promontory electrode or cochlear implant, which is not possible using functional magnetic resonance imaging (fMRI). Although PET has been introduced in this context decades ago, its feasibility when performed during general anesthesia has not yet been explored. However, due to a shift to earlier (and bilateral) auditory implantation, the need to study children during general anesthesia appeared, since they are not able to cooperate during scanning. Therefore, we evaluated retrospectively results of individual SPM (statistical parametric mapping) analysis of 15O-water PET in 17 children studied during general anesthesia and compared them to those in 9 adults studied while awake. Specifically, the influence of scan duration, smoothing filter kernel employed during preprocessing, and cut-off value used for statistical inferences were evaluated. Frequencies, peak heights, and extents of activations in auditory and extra-auditory brain regions (AR and eAR) were registered. RESULTS: It was possible to demonstrate activations in auditory brain regions during general anesthesia; however, the frequency and markedness of positive findings were dependent on some of the abovementioned influence factors. Scan duration (60 vs. 90 s) had no significant influence on peak height of auditory cortex activations. To achieve a similar frequency and extent of AR activations during general anesthesia compared to waking state, a lower cut-off for statistical inferences (p < 0.05 or p < 0.01 vs. p < 0.001) had to be applied. However, this lower cut-off was frequently associated with unexpected, "artificial" activations in eAR. These activations in eAR could be slightly reduced by the use of a stronger smoothing filter kernel during preprocessing of the data (e.g., [30 mm]3). CONCLUSIONS: Our data indicate that it is feasible to detect auditory cortex activations in 15O-water PET during general anesthesia. Combined with the improved signal to noise ratios of modern PET scanners, this suggests reasonable prospects for further evaluation of the method for clinical use in auditory implant users. Adapted parameters for data analysis seem to be helpful to improve the proportion of signals in AR versus eAR.

15.
Eur J Nucl Med Mol Imaging ; 45(5): 824-845, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29234845

RESUMO

Radium Ra-223 dichloride (radium-223, Xofigo®) is a targeted alpha therapy approved for the treatment of castration-resistant prostate cancer (CRPC) with symptomatic bone metastases and no known visceral metastatic disease. Radium-223 is the first targeted alpha therapy in this indication providing a new treatment option, with evidence of a significant survival benefit, both in overall survival and in the time to the first symptomatic skeletal-related event. The skeleton is the most common metastatic site in patients with advanced prostate cancer. Bone metastases are a clinically significant cause of morbidity and mortality, often resulting in bone pain, pathologic fracture, or spinal cord compression necessitating treatment. Radium-223 is selectively accumulated in the bone, specifically in areas of high bone turnover, by forming complexes with the mineral hydroxyapatite (the inorganic matrix of the bone). The alpha radiation generated during the radioactive decay of radium-223 produces a palliative anti-tumour effect on the bone metastases. The purpose of this guideline is to assist nuclear medicine specialists in evaluating patients who might be candidates for treatment using radium-223, planning and performing this treatment, understanding and evaluating its consequences, and improving patient management during therapy and follow-up.


Assuntos
Neoplasias Ósseas/radioterapia , Neoplasias de Próstata Resistentes à Castração/radioterapia , Rádio (Elemento)/uso terapêutico , Neoplasias Ósseas/secundário , Europa (Continente) , Humanos , Masculino , Guias de Prática Clínica como Assunto , Radioisótopos
16.
Adv Ther ; 34(4): 986-994, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28265811

RESUMO

INTRODUCTION: The bone scan index (BSI) was introduced as a quantitative tool for tumor involvement in bone of patients with metastatic prostate cancer (mPCa). The computer-aided diagnosis device for BSI analysis EXINIboneBSI seems to represent technical progress for the quantitative assessment of bone involvement. But it is not yet clear if the automated BSI (aBSI) could contribute to improved evaluation of progression in patients under antiandrogens or chemotherapy in contrast to the visual interpretation and/or conventional biomarkers such as the prostate-specific antigen (PSA). METHODS: In 49 mPCa patients, bone scans were performed initially and during different therapy courses. Scans were evaluated visually and by the artificial-neural-network-based expert system EXINIboneBSI. Progression of metastatic bone involvement was defined according to the Prostate Cancer Clinical Trials Working Group 2 (PCWG2) criteria in the visual interpretation. The computer-assisted interpretation was based on different cutoff values in relative changes of the aBSI. Additionally, assessments according to bone scanning were compared to changes in the PSA value as a potential surrogate for treatment response. RESULTS: Using a sensitive cutoff value (5% or 10%) for the relative aBSI increase led to significantly increased progression determination compared to the visual interpretation of bone scans (49% and 43% vs. 27%, p < 0.001). In 63% of the cases PSA and BSI changes matched, whereas in 18% progression was only indicated by the aBSI. A relative cutoff of 5% for the aBSI decrease could reclassify 47 serial scan pairs which were visually interpreted as stable into 22 progressive and 25 remissive scans. CONCLUSION: Distinct thresholds of the relative aBSI could help to better assess disease progression in mPCa patients. Manual corrections of the BSI values are not required in most cases. The aBSI could serve as a useful additional parameter for therapy monitoring in mPCa patients in the future.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Sistemas Inteligentes , Neoplasias da Próstata/patologia , Idoso , Progressão da Doença , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Cintilografia , Estudos Retrospectivos
17.
Clin Nucl Med ; 42(6): e286-e293, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28221194

RESUMO

PURPOSE: The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. METHODS: Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. RESULTS: Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P < 0.01). The influx rate (Ki) was higher in prostate cancer than in reference prostate gland (0.055 [r = 0.998] vs 0.017 [r = 0.996]). CONCLUSIONS: Primary prostate cancer is readily identified on early dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.


Assuntos
Ácido Edético/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Ligantes , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/diagnóstico por imagem , Próstata/cirurgia , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Fatores de Tempo
18.
Z Med Phys ; 27(1): 49-55, 2017 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-27431973

RESUMO

Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined.


Assuntos
Radioisótopos de Gálio , Resíduos Radioativos , Compostos Radiofarmacêuticos , Gerenciamento de Resíduos , Humanos , Tomografia por Emissão de Pósitrons , Radioisótopos
19.
Eur Heart J ; 38(6): 436-443, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-27469371

RESUMO

Aims: High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with 111In-labeled white blood cells (WBCs) and myocardial perfusion with 99mTc-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results: A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves (n = 12) or implants (n = 22). Simultaneous 111In-WBC/99mTc perfusion imaging was performed, and compared with standard 111In-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on 99mTc images was not observed for 111In activity as high as 2.5*99mTc activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy (P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging (P < 0.001). Conclusion: Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with 111In and 99mTc is feasible and aids in the workup of suspected endocarditis.


Assuntos
Endocardite/diagnóstico por imagem , Radioisótopos de Índio , Leucócitos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas
20.
Nuklearmedizin ; 55(5): 177-86, 2016 Sep 26.
Artigo em Alemão | MEDLINE | ID: mdl-27417067

RESUMO

This document describes the guideline for therapy of bone metastases with radium-223 ((223)Ra) published by the Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften in Germany (AWMF) under the auspices of the Deutsche Gesellschaft für Nuklearmedizin (DGN), Östereichische Gesellschaft für Nuklearmedizin (OGN), and Schweizerische Gesellschaft für Nuklearmedizin (SGNM). This guidance is based on an interdisciplinary consensus. These recommendations are a prerequisite for the quality management in the treatment of patients with bone metastases from prostate cancer using (223)Ra. They are aimed at guiding nuclear medicine specialists in selecting candidates to receive therapy and to deliver the treatment in a safe and effective manner. The document contains background information and definitions. It covers the rationale, indications and contraindications for therapy with (223)Ra. Essential topics are the requirements for institutions performing the therapy, which patient data have to be available prior to performance of therapy, and how treatment has to be carried out technically and organisationally. Moreover, essential elements of follow-up and aftercare are specified. As a matter of principle, the treatment inclusive aftercare has to be realised in close cooperation with the involved medical disciplines.


Assuntos
Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Medicina Nuclear/normas , Guias de Prática Clínica como Assunto , Radioterapia/normas , Rádio (Elemento)/uso terapêutico , Medicina Baseada em Evidências , Alemanha , Compostos Radiofarmacêuticos/normas , Compostos Radiofarmacêuticos/uso terapêutico , Rádio (Elemento)/normas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...